T-Tape Drip Tape

T-Tape Drip Tape Features

  • Turbulent-flow dripper technology provides a high level of flow rate uniformity
  • White stripe with product information for easier installation and storage
  • Self-closing slit outlet (ideal for SDI systems)
  • Install on the ground, under opaque plastic, or even subsurface

One of the most recognized and trusted drip tape brands in the world, T-Tape Drip Tape is used in a variety of crops around the world to help reduce water consumption, increase crop quality, and increase crop yields. T-Tape Drip Tape can be installed on the ground, under plastic, or even subsurface. Because of T-Tape’s material strength, design, and quality production standards, it’s the drip tape that you can count on year after year.

T-Tape is available in a wide assortment of configurations, including various lengths, wall thickness, emitter spacings and flow rates. Helping growers match individual growing situations with maximum yield benefits.

Applications

  • Surface
  • Under Mulch (buried)
  • Subsurface

Suggested Use of T-Tape Drip Tape

5/8″ (5 mil): Short season crops in medium tilled soils that contain slight residue from a previous crop. Beneficial for crops such as strawberries, melons and onions.

5/8″ (6 mil): Minimum tilled soils, double cropping, medium textured soils or where rocks or previous crop residue is a factor. Commonly used in tomatoes, peppers, melons and strawberries.

5/8″ and 7/8″ (8 mil): Minimum tilled soils, double cropping, heavier tilled soils, or where more resistance to abrasion and insect damage is desired. Used in peppers, tomatoes, melons and vegetable crops.

5/8″ and 7/8″ (10 mil): Heavy or rocky soil, where insects are a problem, where it is to be moved or reused for multiple seasons.

5/8″ and 7/8″ (15 mil): Heavier soil or soils presenting rougher terrain where insects are a stronger threat, even small animals. Used in sugarcane, asparagus and SDI applications. T-Tape is the solution to the challenges faced by growers. T-Tape was developed to meet the individual grower’s needs.

Diameters 16, 22, 29 mm
Wall Thickness 5, 6, 7, 8, 10, 15 mil
Dripper Spacings 10, 15, 20, 30, 40, 50 cm
Flow Rates 125 – 1350 LPH/100 m
Diameter / Emitter Spacing Flow Rate Roll Length
Wall Thickness (cm) (lph / 100m) (m)
16 mm – 500 Series
5 mil 10, 15, 20, 30 90, 125, 170, 250, 340, 380, 500, 750 3658, 3962
6 mil 10, 15, 20, 30, 40 125, 170, 250, 340, 380, 500, 750, 1000, 1350 3050
7 mil 10, 15, 20, 30 250, 500, 1000, 1350 1400, 2800
8 ml 10, 15, 20, 30, 40 125, 170, 190, 250, 340, 380, 500, 750, 1000, 1350 500, 1150, 2300
10 mil 10, 15, 20, 30 40,60, 90 170, 230, 250, 340, 380, 500, 750, 1000 1830
12 mil 12, 20, 30 250, 340, 500 1550
15 mil 20, 30, 40, 50 185, 250, 315, 340, 380, 500 1250
22 mm – 700 Series
6 mil 15, 20, 25, 30 170, 250, 300, 340, 500 2250
7 mil 20, 30 250, 340, 500 1972
8 mil 20, 30 170, 250, 340, 380, 500 1695
10 mil 15, 20, 30 170, 250, 340, 380, 500 1220, 1340
12 mil 12, 20, 30 170, 250, 340, 500 1135
15 mil 20, 30, 40 170, 185, 210, 250, 315, 340 823, 915, 1585
29 mm – 900 Series
8 mil 30 250 1700
Recommended operating pressure: 0,55 bar
Flow rate per outlet: 0,5-1,35 lph
Product Options
Wall Thickness 5, 6, 7, 8, 10, 15 mil
Dripper Spacings 10, 15, 20, 30, 40, 50, 60, 90 cm
Rolls per Pallet Container: 16
Truck: 20
Roll Weight 29 Kg
Roll Length 500 – 3962 m

 

Operating Guidelines
Recommended operating pressure 0,55 bar

 

Operating Pressure by Model
Model Operating Pressure (bar)
505, 706, 707, 908 0,30 – 0,56
506, 708 0,30 – 0,70
508, 510, 512, 515 0,30 – 1,05
710, 712, 715 0,30 – 1,05
Product Information Operating Data
Dia.
(inch)
Wall
(mil)
Spacing
(inch)
Flow Rate*
(gpm /100 ft)
Flow
Rate *(gph)
Flow
Rate Class
Rec. Filtration Max. Op.
Pressure (psi)
Max. Flush
Pressure (psi)
Max .Length
of Run** (ft)
(mesh) (micron)
7/8 6 8 0.34 0.14 Low 200 80 8 10 1030
7/8 8 8 0.34 0.14 Low 200 80 10 12 1030
7/8 8 8 0.50 0.20 Med 150 100 10 12 795
7/8 8 8 0.67 0.27 Med 150 100 10 12 665
7/8 8 12 0.22 0.13 Low 200 80 10 12 1350
7/8 8 12 0.34 0.20 Med 150 100 10 12 1030
7/8 8 12 0.45 0.27 Med 150 100 10 12 865
7/8 10 6 0.45 0.14 Low 200 80 15 16 865
7/8 10 8 0.34 0.14 Low 200 80 15 16 1030
7/8 10 8 0.67 0.27 Med 150 100 15 16 665
7/8 10 12 0.34 0.20 Med 150 100 15 16 1030
7/8 10 12 0.45 0.27 Med 150 100 15 16 865
7/8 12 8 0.34 0.14 Low 200 80 15 19 1030
7/8 12 12 0.27 0.16 Low 200 80 15 19 1200
7/8 12 12 0.45 0.27 Med 150 100 15 19 865
7/8 15 8 0.34 0.14 Low 200 80 15 23 1030
7/8 15 8 0.67 0.27 Med 150 100 15 23 665
7/8 15 12 0.22 0.13 Low 200 80 15 23 1350
7/8 15 12 0.22 0.13 Low 200 80 15 23 1350
7/8 15 12 0.22 0.13 Low 200 80 15 23 1350
7/8 15 12 0.34 0.20 Med 150 100 15 23 1030
7/8 15 12 0.45 0.27 Med 150 100 15 23 865
7/8 15 16 0.28 0.23 Med 150 100 15 23 1165
*Flow rates calculated at 8 psi.
** Length of runs calculated using Hydraulic Tool.
Roll Length – 16 mm
5 mil 3658, 3962 m
6 mil 3050 m
7 mil 1400, 2800 m
8 mil 500, 1150, 2300 m
10 mil 1830 m
12 mil 1550 m
15 mil 1250 m

 

Roll Length – 22 mm
6 mil 2250 m
7 mil 1972 m
8 mil 1695 m
10 mil 1220, 1340 m
12 mil 1135 m
15 mil 823, 915, 1585 m

 

Roll Length – 29 mm
8 mil 1700 m
Product Information Operating Data
Dia.
(inch)
Wall
(mil)
Spacing
(inch)
Flow Rate*
(gpm /100 ft)
Flow
Rate *(gph)
Flow
Rate Class
Rec. Filtration Max. Op.
Pressure (psi)
Max. Flush
Pressure (psi)
Max .Length
of Run** (ft)
(mesh) (micron)
1 ⅜ 15 12 0.22 0.13 Low 200 80 15 16 2876
1 ⅜ 15 12 0.34 0.20 Medium 150 100 15 16 2232
1 ⅜ 15 12 0.45 0.27 Medium 150 100 15 16 1884